Aluminum furniture frame mobility conversion sounds like a simple exchange of fixed feet for casters. The decision changes how the load reaches the floor, however, and the existing frame may never have been approved for pushing, braking, or repeated movement. Before requesting cut members or a saw quote, establish what the furniture must carry, how it will move, who owns the retrofit design, and which interfaces are already approved.
This guide is for buyers of aluminum-profile worktables, carts, and similar industrial furniture. It separates a hardware-only change from a base redesign or a new mobile frame. The example photographs show general profile-frame construction; they do not certify a particular caster, load rating, retrofit, customer installation, or Jiurun machine configuration.

Start with the use case, not a caster catalog
Write down whether the unit will be repositioned occasionally while empty, moved under load, or used as a regular transport cart. These are different duties. Record the maximum intended payload, the frame’s own weight, the height of the center of mass, the floor surface, thresholds, slopes, travel distance, and the frequency of movement. Note whether a person may lean on the worktop or whether the unit carries a machine that creates vibration. The responsible designer must assess these conditions; a caster’s catalog capacity alone does not approve the complete frame.
Map the travel route before choosing wheels. Door clearances, turning space, uneven joints, and access to a brake pedal can determine whether the furniture is usable. If the unit must remain stable during work, define how it will be restrained: wheel brakes, a floor lock, leveling feet that take the load when parked, or a different approved arrangement. Do not assume that a braked swivel caster makes every tall or offset load stable.
Manufacturer catalogs illustrate the range of choices. 80/20 lists casters, leveling feet, floor locks, and mounting bases; item describes direct and base-plate caster mounting alongside adjustable feet and floor fixings. These are examples of connection families, not evidence that a specific part fits the buyer’s existing frame.
Survey the installed frame before promising reuse
Identify the profile series and actual section, not just an outside dimension that looks familiar. Record the end-face core bore, slot geometry, wall condition, current foot attachment, corner connector, and access for tools. Photograph all four lower corners and any cross members. Check whether the feet are threaded into an insert, fastened to a plate, or integrated into a welded or proprietary base. Request the original drawing and bill of materials if available.
Look for damage and previous changes. A frame with loose joints, distorted legs, elongated holes, corrosion, missing fasteners, or an undocumented extension needs engineering review before anyone orders wheels. Measure the as-built footprint and worktop height. Adding a caster changes the working height and may move the contact points inward or outward; both can change the buyer’s operating envelope. If there is a mounted machine, obtain its maker’s movement and anchoring instructions before changing the base.

Four purchase routes after the survey
| Route | When it might be appropriate | What the quote must identify |
|---|---|---|
| Approved hardware retrofit | The frame designer confirms that the existing legs and joints accept a named mounting method and mobile duty. | Specific casters, plates or inserts, fasteners, brakes, installation labor, and acceptance checks. |
| New lower supports or base members | The upper frame remains suitable but lower members, cross bracing, or mounting points must change. | Revision-controlled cut list, profile identity, drilling or tapping scope, connector set, finishing, and assembly responsibility. |
| Engineered mobile module | A separate approved base can carry the upper structure without improvising at the old foot joints. | Base drawing, attachment boundary, load assessment, height, transport/parking method, and site fit trial. |
| Complete new mobile furniture | Frame history, load path, dimensions, or approvals are uncertain, or the retrofit is uneconomic. | Whole-unit design, payload and use case, caster specification, delivery form, and final acceptance. |
The first route is often the smallest purchase order but has the highest risk of being treated as a mechanical afterthought. The second can involve Jiurun’s relevant scope if the buyer needs accurately cut aluminum profile members. Jiurun supplies aluminum cutting equipment; it does not automatically design or approve the finished mobile furniture. Keep that boundary explicit in the RFQ.
When new cut members are in scope
If the designer calls for new legs, cross members, or a complete lower rectangle, provide a revision-controlled drawing and one cut-list line per distinct member. Identify the extrusion section and material specification supplied by the buyer, cut length datum and tolerance, end condition, angle or miter requirement, visible-face protection, quantity per unit, and the number of units. Mark which holes, taps, inserts, plates, or welds belong to later operations. A saw-cut member is not a finished caster mount unless those operations are expressly included and verified.
Ask whether parts will arrive as raw cut lengths, labeled frame kits, or assembled bases. A kit should group the correct left/right and front/rear members with their matched connector list. Do not let a quoted piece count conceal missing hardware. The furniture-frame kit receiving guide gives a separate handover check, while the furniture-frame saw-trial guide covers visible faces and corner fit before repeat cutting.

Make the caster interface and responsibility visible in the RFQ
For each proposed wheel position, identify the approved attachment route: a tapped profile end, a compatible insert, a base plate, or another designed connection. The item swivel-caster product page shows that its own fitting options can depend on a core thread or base plate and may require machining. This is a product example only; do not transfer its dimensions, loading, or attachment method to an unrelated frame.
Request a complete interface drawing that shows the caster or leveling foot, fastener engagement, plate orientation, clearances, and final overall height. Require the designer to state the applicable load case and whether floor braking, wheel braking, leveling, or anchoring is needed for the intended use. The installer should confirm that the chosen brake or lock can actually be reached without trapping fingers or blocking nearby equipment. The buyer should assign one party to approve the complete unit, including its stability when moving and parked.
Separate commercial lines for the hardware, cut aluminum members, secondary machining, connectors, assembly, on-site changeover, and acceptance. If the existing frame’s identity cannot be proven, record that uncertainty. A supplier should not silently substitute a similar profile or promise a safe conversion from a photograph.
Test one unit before releasing a fleet
Build or convert a first unit against the approved revision. Verify that all wheels contact the floor as intended, the frame tracks and turns on the actual route, brakes or leveling elements operate as specified, worktop height remains usable, and doors, panels, and access covers can still open. Inspect the connection points after the trial under the agreed representative load. If the original design requires a stationary anchored frame, stop and obtain design approval rather than treating a rolling trial as permission.
Document findings with a marked drawing and photographs. Record the person who accepted the configuration, the approved hardware identifiers, any rework, and the date from which repeat kits may be ordered. If a member changes, revise the cut list and do not mix old and new sets in one release. For a spare-only issue on an existing approved frame, see the separate furniture-frame spares decision guide.
What to send for an accurate quotation
- The existing frame drawing or measured as-built sketch, lower-corner photographs, and profile identity.
- Payload and movement duty, floor and route conditions, parking/stability requirements, and any mounted equipment instructions.
- The approved choice among hardware retrofit, new base members, mobile module, or complete unit.
- For cut members: controlled revision, section, lengths, end conditions, quantities, finish protection, kit grouping, and downstream machining boundary.
- The specified caster/foot/base-plate part numbers or an explicit request for the responsible designer to select them.
- First-unit fit-trial criteria, owner of full-unit approval, delivery format, and repeat-order release condition.
Equipment video: The Jiurun Machinery channel clip below shows general aluminum cutting equipment footage. It is not a demonstration of the furniture frame, caster interface, customer installation, retrofit approval, load test, or performance discussed here.
If new aluminum members are required, send Jiurun the approved profile drawing and cut list with the responsibility boundary clearly marked. We can discuss an appropriate aluminum cutting workflow for those parts; the completed mobile furniture and caster selection remain subject to the buyer’s qualified design approval. Send your drawing for a cutting discussion.