Star vs delta voltage on a motor nameplate needs the voltage numbers and their connection symbols read together. Preserve the frequency and other data on the same rated line. A motor’s paired voltage entries do not state the supply requirement of an entire aluminum-cutting machine.
For purchasing, collect the complete nameplate record and the manufacturer’s applicable documents. Have the machine supplier and qualified electrical reviewer confirm the proposed configuration for the actual site.
On this page
Check 1: read star vs delta voltage with the symbols
Siemens’ SINAMICS V20 operating instructions, May 2022, show an IEC motor rating-plate example on printed page 222. Its 50 Hz line includes 230/400 V with Δ/Y symbols.
In that example, Δ identifies delta and Y identifies star. The voltage entries pair with those symbols: 230 V with Δ and 400 V with Y. Retain the pairing when recording the example.
| Nameplate entry | Label retained |
|---|---|
| 230 V Δ | Delta-rated entry at the stated frequency |
| 400 V Y | Star-rated entry at the stated frequency |
| 50 Hz | Frequency belonging to that rated line |
These entries come from Siemens’ illustrative plate. They are not ratings for a JiurunCut motor or instructions to connect an unidentified motor. The actual offered equipment requires its own confirmed documentation.
The paired notation should not be shortened into an unrestricted operating range. Ask the manufacturer to explain the actual rating if a seller removes the symbols or separates the numbers from their headings.
Keep the full motor reference with the photograph or document. An example from a drive manual helps explain a notation; it does not establish the specification of a replacement component that merely looks similar.

Check 2: keep the frequency and related fields on the same line
The Siemens example also presents a separate 60 Hz rated entry. Its structure shows why the frequency heading belongs with the electrical and mechanical data beneath it.
When collecting the actual motor information, take a readable record of the complete plate rather than a cropped voltage fragment. Ensure every row heading and applicable symbol can be identified.
Keep each frequency’s stated fields together in the review sheet. If the plate contains more than one rated line, label them separately. Do not take voltage from one line and a convenient speed from another without a manufacturer’s explanation.
Ask which rated entry is applicable to the proposed machine configuration. If the quotation does not identify it, retain the question as pending clarification. A country name does not replace the actual equipment and site information.
For the rotation fields, our synchronous versus rated speed guide explains the separate motor-speed question. Keep the reported speed and its conditions connected to the correct motor.
Preserve the units as well. Voltage, frequency, current and shaft power occupy different fields. A purchasing spreadsheet should retain their names instead of placing several bare numbers in one “motor data” cell.
For unreadable or unfamiliar notation, ask the supplier for a legible manufacturer record. Do not reconstruct a missing symbol from a general catalog example or a photograph of another machine.

Check 3: separate the motor rating from machine supply requirements
A motor nameplate identifies an individual component. The complete equipment quotation needs the electrical requirements for the supplied machine, its control arrangement and the accessories included in the package.
Obtain the machine manufacturer’s applicable supply specification and document revision. Connect them to the exact ordered configuration. The component record should support that review rather than replace it.
Have qualified site personnel provide the installation-location information needed by the equipment supplier. Preserve the stated site voltage, phase and frequency with their source reference.
The saw power-supply quotation guide organizes this equipment-level review. It also helps keep motor output separate from complete connected-load information.
If the site information differs from the proposed equipment requirements, ask the responsible parties to resolve the configuration before ordering. An electrical adaptation is a separate design question that the component voltage row cannot settle.
Keep proposed component changes visible. If a motor or drive option changes, ask the machine supplier to review the affected documents and any earlier compatibility conclusion.
Connection work, protection selection and drive configuration belong with qualified personnel following the actual equipment documentation. This guide provides a reading and purchasing checklist, with no terminal-link arrangement or programming procedure.
Two incomplete quotation rows require different questions
Imagine an invented inquiry for an unconfirmed machine configuration. Offer A lists only “motor 400 V.” Offer B supplies a complete component plate but gives no machine-level electrical specification.
For A, request the full motor reference and rated entry, including symbols and frequency. A bare voltage does not preserve the nameplate’s complete description.
For B, retain the component record and request the equipment specification for the exact supplied version. The complete plate answers a component question, while the omitted document concerns the machine package.
Then have the supplier and site reviewer assess the same intended configuration. Keep their confirmed conclusion and any conditions with the final quotation.
This example is a fictional document comparison. It contains no approved motor connection, installation design or actual compatibility finding. Neither offer becomes acceptable simply by adding a matching number to the review sheet.
Prepare one clear package for the configuration review
- Equipment: the quoted machine, options and applicable document revision.
- Motor: the exact reference and readable complete nameplate record.
- Site: the confirmed supply information for the intended location.
- Accessories: the separate items included in the actual electrical review boundary.
- Open questions: missing records or proposed configuration changes.
Send these records together rather than forwarding an isolated motor photograph. Identify who supplied each item and which version the final review covers.
For the cutting task, include the section drawing, material condition, required lengths, quantities and intended workflow. That brief lets the supplier connect configuration questions to the actual equipment proposal.
If the quoted equipment changes after review, update the record and request confirmation of the affected requirements. Keep the earlier document available so the revision remains understandable.

Send JiurunCut your cutting brief and confirmed site information. Ask for the electrical documents applicable to the proposed machine version, with the responsible site reviewer included in the discussion.
Buyer questions about star vs delta voltage
Can I discard Δ and Y after copying the voltages?
Keep the symbols and their pairing. They carry information that the numbers alone omit.
Does the Siemens example approve a particular saw connection?
Use the actual machine and component documentation for the equipment being ordered.
Does a complete motor plate settle the site review?
Obtain the complete equipment requirements and have the responsible parties review the actual site arrangement.