An aluminum saw MQL lubricant change is a purchasing and release decision, not just a reservoir refill. A replacement fluid may arrive with a plausible label while the machine still contains an unknown amount of the previous product. Before production resumes, identify the exact fluid, obtain the machine supplier’s changeover instruction, and record what was actually checked on the first accepted part. This guide is for teams reviewing an MQL-equipped aluminum saw; it does not specify a lubricant or a universal purge procedure for a Jiurun machine.
Start with the two named fluids
Write down the current product and proposed replacement by manufacturer, product name, grade, and batch or container reference. If the old product is unknown, say so. Do not turn “MQL oil” into a substitute specification: different formulations and delivery components can impose different limits. The lubricant supplier should confirm suitability for the alloy, blade, downstream cleaning or bonding steps, and the intended application. The saw supplier should confirm compatibility with the actual reservoir, seals, lines, metering device, and nozzle arrangement. Ask both parties whether residual old fluid can remain and what evidence supports their answer.
MQL is commonly described as a system that uses a small, fresh supply of lubricant rather than recirculating a flood coolant. That distinction matters when planning a change, but it does not prove that two products can be mixed. The UNIST MQL Handbook explains the delivery principle; it is general industry guidance, not a fluid approval for this saw.
Separate an approved changeover from a top-up
A top-up adds fluid to a known, approved system. A changeover replaces the product and needs a boundary between old and new material. Ask for a written, machine-specific sequence that identifies who isolates the equipment, which components are drained or cleaned, whether lines require purging, how the new product is introduced, and how waste is handled under the site’s rules. The exact steps must come from the equipment and lubricant suppliers and the site’s competent staff. Do not infer them from a photograph or from another manufacturer’s manual.
For perspective, Haas’s MQL service guidance includes a purge after a fluid change on its own equipment. That is evidence that the fluid boundary can matter; it is not a Jiurun procedure or permission to copy the Haas steps. If a supplier says no purge is needed on the quoted saw, request that conclusion in writing for the named old and new fluids and the actual installed system.

MQL lubricant change: what the release record must show
An MQL lubricant change cannot be released from the container label alone. One signed sheet is more useful than an undocumented “fluid changed” note. Give the maintenance and production teams a common record with the following fields:
- Product identity: old and new lubricant names, grades, containers, dates, and the supplier approval for this machine and material.
- Changeover authorization: the machine-specific instruction and the person who completed it, including any approved drain, clean, or purge record.
- Delivery observation: the observed liquid delivery at the relevant point under the approved setup, with any abnormal result escalated. Air movement alone does not establish lubricant delivery; see our separate MQL flow check.
- First accepted part: the representative profile, blade and program identifiers, cut-face and dimensional checks, and the reviewer who released production. Record what was measured; do not invent a universal acceptance limit.
A low-level alarm or refill event belongs in a different record. It may prompt a response, but it does not by itself show that a new product is compatible or the changeover is complete. Our lubricant-level warning guide addresses that separate trigger.

What the equipment video shows
The following video from Jiurun’s own channel shows an automatic aluminum cutting machine operating. It provides equipment context only. The footage does not demonstrate the lubricant product, MQL configuration, changeover steps, first-part result, or compatibility of any fluid discussed above.
Before approving a replacement lubricant
Ask the saw supplier and lubricant supplier to review the exact old product, proposed new product, installed MQL components, aluminum profile, blade, and downstream process. Request their written compatibility decision and the machine-specific changeover instruction. Then agree on the first-part inspection and who signs the release. If any of those inputs are unknown, keep the approval conditional until they are established. A general product brochure, machine video, or clean-looking cut face cannot close the gap.
For a Jiurun equipment inquiry, send the machine model and serial or quotation reference, photos of the installed lubrication components, both lubricant product sheets, and a representative profile drawing. Jiurun can review the equipment side of the question against the actual configuration; the lubricant manufacturer should confirm its product’s material and application limits. Contact Jiurun with those records before treating the replacement as released.